ERROR type fault messages

All faults of the ERROR type must be reset manually:

RM10.5T, RMS10.5T, RMS10.5XT: Press the control knob for 2 seconds.

RM10.5S, RMS10.5S, RMS10.5XS: Press for 2 seconds.

✓ A beep sounds.

✓ The error has been reset.

ERROR type Fault description Solution
E03 No connection between power module and display Contact an authorized customer service point.
E07 No cooling capacity in gas mode   

Check if the device is at an angle and adjust it so it is level, if necessary. Reset the error. Contact customer service if this error occurs again.

E08 No cooling capacity in AC power mode

Check if the device is at an angle and adjust it so it is level, if necessary. Reset the error. Contact customer service if this error occurs again

E09 No cooling capacity in DC power mode

Check if the device is at an angle and adjust it so it is level, if necessary. Reset the error. Contact customer service if this error occurs again.

E12 Gas valve test error Gas operation not possible

Reset the error. Contact customer service if this error occurs again.

E13 Internal communication error Gas operation not possible Reset the error.
Contact customer service if this error occurs again
E14 In stand-alone gas mode: The battery charge of the battery packs is too low Insert new batteries and then reset the error
E50 Gas lock after 3 ignition attempts   Ignition not possible.
The gas cylinder is empty.
Replace the gas cylinder.
Reset the error.
E51 Gas lock, internal error in the power module

Reset the error.
Contact customer service if this error occurs again.

E52 Ground contact, gas valve Reset the error

Contact customer service if this error occurs again.

E53 Ground contact, ignition electrode

Reset the error. Contact customer service if this error occurs again